Self Cleaning Screen Mesh is made of high carbon steel wire or stainless steel wire (material Parameter is refer from Vibrating Screen Mesh) . It can offer effective solutions to difficult sizing and aggregate separation conditions, such as the blinding and plugging. Self cleaning screen mesh can separating and screening the wet and moist materials. It is widely used in the separating materials in the mining, quarry and other industries.
Specifications:
Features
· Control strictly for the sizing.
· Self-cleaning ability and less maintenance.
· Three different types – W mesh, H mesh and D mesh.
· Reduce the blinding and plugging.
· Wear and abrasion resistance.
· Producing tighter specifications and having the ability to self-clean.
· Customized width and length is available.
Applications Self Cleaning Vibrating Screen Mesh Self Cleaning Vibrating Screen Mesh,Water Filter Screen,Self Cleaning Filter,Self Cleaning Water Filter Anping Huahaiyuan Wire Mesh Co.,ltd , http://www.crusherscreenmesh.com
Main Applications:
Turbine flow flowmeter adapts to measure the liquid rate and total flow rate of low viscosity, It can be widely used in the fields of Petrol,fuel ,water ,chemical industry,Metallurgy,Scientific research for measuring or control Several output and display methods can be selected.
Â
Features:
-Accuracy reaching ±1.0%F·S.
-Short-term repeatability reaching 0.05%~0.2%.
-Output pulse frequency signal, which is suitable for gross metering and connection to the computer. - Â -No zero drift and strong anti-interference capability.
-3-4kHz frequency signal , and high signal resolution.
-Wide range with 1:20 for medium and large caliber, 1:10 for small caliber.
-Compact and light structure, convenient installation and maintenance, great capability.
-Suitable for measuring high pressure. Easy to be made into high-pressure meter.
-Various kinds of specified sensors.
Â
Technical parameters:
Table 3-1
Nominal Diameter
DN(mm)Range(m3/h)
Liquid Temperature
(ºC)Nominal Pressure
PN(MPa)Ambient Temp.
(ºC)Humidity
(%)Max. Pressure Loss
(MPa)
Error Â
0.2%*Error   0.5%
Error     1%
Min.
Max.
Min.
Max.
Min.
Max.
2*
Â
Â
Â
Â
0.03
0.16
-20
 to
+1206.3
-25
to
+55≤ 80
0.15
4*
Â
Â
Â
Â
0.04
0.25
0.12
6
Â
Â
0.1
0.6
0.1
0.6
6.3
16
25
32*0.08
10
Â
Â
0.25
1.2
0.2
1.2
0.05
15
1.2
6
0.6
4
0.6
6
0.035
25
2
10
1.6
10
1
10
40
4
20
3
20
2
20
1.6
2.50.025
50
6
40
4
40
4
40
80
16
100
10
100
10
100
100
25
160
20
160
20
200
1.6
2.5
150
50
300
40
300
40
400
200
150
750
100
600
80
800
250*
200
1000
160
1000
120
1200
1.6
300*
Â
Â
260
1600
180
1800
Â
Table 3-2 Model and Specification Code
Model
Specification Code
Description
LW.......................................................................................
Turbine Flowmeter
Transducer
For Liquid
Â
G........................................................................
Â
Y......................
Nominal Diameter
-2*.................................................
-4*.................................................
-6..................................................
-10................................................
-15................................................
-25................................................
-40................................................
-50................................................
-80................................................
-100..............................................
-150..............................................
-200..............................................
-250..............................................
-300..............................................2mm(PT G3/8″)
4mm(PT G3/8″)
6mm(PT G3/8″)
10mm(PT G1/2″)
15mm(PT G1″)
25mm(PT G11/4″)
40mm(Flange)
50mm(Flange)
80mm(Flange)
100mm(Flange)
150mm(Flange)
200mm(Flange*)
250mm(Flange*)
300mm(Flange)
Type Code
A............................ ..........
B............................ ..........
C............................ .......Accuracy 1%
Accuracy 0.5%
Accuracy 0.2%*
Output Signal
P......................... .......
I.......................... .......
T......................... .......
M........................ .......Pulse
Analog 4 to 20mA
Total display(Battery. for 2 to 3 years)
Pulse out/4 to 20mA out and LCD display(Intelligent)
Diameter Pressure
C1................... .....
C2................... .....
C3................... .....
C4................... .....
C5................... .....
C6................... .....
C7................... .....PN1.6MPa
PN2.5MPa
PN4.0MPa
PN6.3MPa
PN16MPa(Diameter≤25mm)
PN25MPa(Diameter≤25mm)
PN40MPa*(Diameter≤25mm)
Explode Request
/NE
/EXNot Explosive
Ex ib I or Ex dIIBT4
Range of Temperature
/NT
/HTNormal Temperature(<120ºC)
High Temperature(≥120 to 150ºC)
Special Option
/
e.g.:High Temperature,Erode-resistant,Wearable etc.
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
Â
       2. Mark "*" means special order.
Material: High carbon steel wire, spring steel wire, manganese steel and stainless steel.
Wire diameter: 1.6mm – 5mm.
Opening size:
5/64″ – 7/8″ for W mesh.
3/64″ – 1-1/2″ for D mesh.
5/64″ – 3/4″ for H mesh.
Edge: Hooked edge is available.
Self cleaning screens effective screening all kind size of the most wet, moist material using in mining, quarry, aggregate processing industries.
Model NO.: JH-LWGY
Measuring Media: Liquid
Measuring Principle: Mechanics
Measurement Object: Closed Pipeline
Certification: CE, ISO
Display: LCD
Temperature: -20c~120c
Power Supply: Battery
Output Signal: None
Body Materia: Ss304/Ss316
Connection: Flange or Screw Thread
Trademark: JH
Transport Package: Carton/Wooden Case
Specification: CE, ISO
Origin: Shanghai
HS Code: 9026100000
                                 Liquid Turbine Flowmeter